Medicine & Health
Repeated smartwatch checks made an AI heart-screening signal less jumpy
A Korean study found that requiring repeated positive readings reduced false alarms, while also showing why a watch remains a screening clue rather than a diagnosis.
A single smartwatch reading can be a noisy messenger. Researchers in South Korea tested an AI analysis of watch ECGs for signs of reduced left-ventricular pumping function, first across more than 2,200 people using two watch brands and then during home monitoring.
The brands disagreed on about 9% of paired readings. In the home cohort, 108 people recorded at least five days; requiring two positive days out of three cut false positives among 70 people without the condition from 18 to nine, but it also missed two additional true cases.
Those tradeoffs matter. The preliminary abstract suggests repetition can make screening steadier, not that a watch can diagnose heart failure or replace an echocardiogram and clinician.